IMPORTANT INSTRUCTION
  •  To get better performance install the pumpset between 60% to 80% of its total head capacity.
  • Use appropriate size, good quality cable and starter / protection devices.
  • The Pipe diameter must never be small or big than the pump connections.
  • Read operator’s manual carefully before installation
  •  Use ISI marked cable to minimize voltage losses.
  • Insulate cable carefully and before final cable insulating, each wire should be properly insulated.
  •  Fill clear, cold clean drinking water in deepwell submersible and openwell submersible pumpsets and detailed in operators manual before commissioning.
  •  Pump should not be operated dry run and prevent to protect the pumpset from dry running.
  • Use ISI marked pipes to minimize friction losses.
  •  Number of bends, elbows and T-bends should be minimum as much as possible in the pipe line.
  •  Use air valves in lengthy delivery pipe line to avoid pipe damage.
  •  Pump should be run for few minutes at least once in every day to prevent from seizing.
  •  All pumps employ a prime mover motor suitable for 200-220volts single phase or 380-415 volts three phase, 50Hz,AC Supply.
  •  Starting Method: Upto 7.5 HP – DOL, 7.5 HP and above Star / Delta.
  •  It is mandatory to install our panel board for all our single phase submersible pumpsets
  •  Over load relay setting: For phase current sensing type overload relays the setting to be done for 58% of rated current.
  •  To avoid electric shock or injury by disconnect power before working on or around the pumping system.Only skilled and qualified technician must perform the works complying with local electricity rules and  regulations. To reduce the risk of electric shock during operation an appropriate earthing is mandatory.
  •  Maximum permissible supply voltage should lie between ±10 to 15%
  •  Pipe sizes mentioned mm are nominal pipe sized are nearest conversion of inches, pipe threads are provided as per BSP Standard.
  •  All pump are only suitable for pumping clear, cold, non aggressive, non explosive water without abrasives, solid particles or fiber.

Note : The performance data are at rated voltage and only indicative, actual discharge depends on availability of water in well, based on strength of water source, height of water column, submergence of pump.Friction losses in riser pipe have not been calculated.

In view of continuous developments the information / description / specification / Illustrations are subjects to change without prior notice.

×